High-Temperature Duct and Pipe Thermal Expansion Calculator

A first design-stage estimate for EAF fourth-hole elbows, dedusting ducts, and high-temperature piping runs. The result is calculated from real EN 1993-1-2 carbon steel data — not a constant-coefficient assumption.

This calculator was built specifically for EAF fourth-hole elbows, dedusting ducts, gas ducts, and compensator sizing.

Thermal Expansion Calculator

Length Change

104 mm

Expansion

  • Temperatures are the metal (wall) temperature, not the flue gas temperature. In an EAF duct these can differ by hundreds of degrees.

This calculation is an approximate starting value based on EN 1993-1-2 carbon steel data. For an exact design, talk to DNL's engineers.

How It's Calculated

The calculation uses the formula defined in EN 1993-1-2, clause 3.4.1.1:

ΔL = L × ( e(T_operating) − e(T_installation) )

Where L is the installed length of the pipe or duct, and e(T) is the unit thermal expansion of carbon steel per EN 1993-1-2 clause 3.4.1.1, valid from 20 to 1200°C.

Between 750 and 860°C the expansion stays nearly flat — this is the ferrite-to-austenite phase transformation, not an error in the data.

Enter the metal wall temperature of the pipe or duct — not the flue gas temperature flowing through it. In an EAF duct these can differ by hundreds of degrees.

Why a Single Constant Coefficient Isn't Enough

For a 10 m carbon steel run heated from 20°C to 500°C: the commonly used constant coefficient (12×10⁻⁶ /°C) predicts 57.6 mm of expansion. EN 1993-1-2's actual carbon steel data gives 67.6 mm — meaning the constant-coefficient approach underestimates the real value by 14.8%. At high temperature, that gap can become a real design error in compensator sizing.

Worked Example: A Dedusting Duct Run

A 12 m dedusting duct run, installed at 20°C, grows by roughly 100.8 mm at a 600°C operating temperature. That movement has to be absorbed by properly sized compensators, not fought by the structure.

Reference Table

Assumptions: a 10 m carbon steel run, installed at 20°C.

Operating Temperature (°C)Expansion (mm)
10010
20023.2
30037.2
40052
50067.6
60084
700101.2
800110
900118
1000138
1200178

Frequently Asked Questions

A 12 m dedusting duct run, installed at 20°C, expands by roughly 100.8 mm at a 600°C operating temperature — a real figure calculated from EN 1993-1-2 carbon steel data.

Carbon steel's expansion rate is not linear with temperature, and it nearly flattens between 750 and 860°C due to the ferrite-to-austenite phase transformation. Using a constant coefficient diverges noticeably from the real value, especially above 400°C.

Enter the metal wall temperature. Flue gas temperature and the actual pipe or duct wall temperature can differ by hundreds of degrees, especially on insulated or cooled runs — it's the metal that determines the expansion, not the gas.

Once the calculated expansion exceeds a few centimetres, that movement needs to be absorbed by compensators — otherwise it accumulates as stress on the structure. DNL's engineers size the right compensator type and dimensions based on your calculation result.

That range is carbon steel's ferrite-to-austenite phase transformation. As the crystal structure changes, the material tends to contract slightly, which largely cancels out thermal expansion over that band — producing the near-flat plateau.

No. This tool works only with carbon steel data per EN 1993-1-2. Stainless steel's expansion coefficient depends on the grade, and the two families differ markedly: austenitic grades (1.4301, 1.4404, 1.4541) run roughly 16-18×10⁻⁶/°C, while ferritic grades (1.4509, 1.4521) run roughly 10-11×10⁻⁶/°C — much closer to carbon steel. Picking the right grade changes the result substantially, and the value must come from a verified manufacturer datasheet — contact DNL's engineers and we'll work out the figure for your project.